Close Window

0114 243 3896
Search

Numed Holdings Ltd - Cardiac Diagnostics

PRODUCTS - SPIROMETERS - HANDHELD SPIROMETERS

PulmoLife

A COPD screening device reporting FEV1 and ‘Lung Age’ PulmoLife is a new COPD screening device, designed for quick and easy screening of adult smokers for early detection of COPD. Smokers are at the greatest risk of developing COPD and decline in lung function in susceptible smokers has been shown to be twice that of non-smokers.

This small, innovative device measures FEV1, the measurement of choice in COPD screening. The unit will display a patient’s result together with the FEV1 as a percentage of their predicted value. These results are used to calculate a ‘Lung Age’. The associated ‘Lung Age’ graphical display may help the patient realise the physical damage caused by smoking, encouraging attendance for smoking cessation advice and full spirometry assessment, leading to early diagnosis and appropriate management of COPD.

Suitable for:

  • FEV1 testing programs
  • Identification of early signs of COPD in smokers over 40 or anyone with symptoms
  • Helping susceptible smokers to quit

FEV1 and FEV1 % predicted

Forced Expiratory Volume in the First Second of Expiration. The use of FEV1 is well documented as a useful diagnostic tool for the detection of early COPD. When comparing its result against predicted values and using patients FEV1 result as a percentage of predicted values (FEV1 % predicted) the likelihood and severity of COPD can be seen.

‘Lung Age’

In addition to comparing patients FEV1 results with the predicted reference values for normal subjects, estimation of ‘Lung Age’ can be used to demonstrate to smokers the damage caused to their lungs by smoking in a way they can understand. The ‘Lung Age’ estimation is based on a patients FEV1 results and predicted values. A ‘Lung Age’ example; a 40 year old 5’9" (1.75m) male smoker has an FEV1 of 3.4L giving an estimated ‘Lung Age’ of 52 years. This is because the FEV1 is 100% of the predicted value that a 52 year old would be expected to get.

Features

  • Measures FEV1 — the measurement of choice in COPD screening
  • Gives FEV1 result as a percentage of predicted values
  • 'Lung Age’ Interpretation (Morris and Temple)
  • Used as a motivational tool for smoking cessation

PulmoLife continues the Micro Medical tradition of being accurate and simple to use and provides health professionals with a useful and unique mass-screening tool to help reduce the burden of chronic lung disease.


Specification


  • Transducer:

    Resolution:

    Accuracy:

    Volume Range:

    Flow Range:

    Predicted Values:



    Display:

    Power Supply:

    Dimensions:

    Weight:


    Operating Temperature:

    Operating Humidity:

    Storage Temperature:

    Storage Humidity:

  • Digital Volume Transducer

    0.01L

    +/-3% (meets, and exceeds all known spirometry performance standards)

    0 - 8 Litres

    0-14 Litres/Second

    1) ECCS
    2) NHANES III
    3) Asian (Chinese)

    Custom Liquid Crystal

    3V Lithium Ion Coin Cell Battery

    131 x 59 x 38 mm

    Unit only: 96g
    Unit complete with accessories: 226g

    0 to +40 C

    30% to 90% RH

    -20 to + 70 C

    10% to 90% RH

Bibliography


(1) Nice COPD Guidelines 2004, Thorax 2004: 59 (suppl 1): 1-232

(2) Morris JF, Temple W. Spirometric ‘Lung Age’ estimation for motivating smoking cessation. Preventative Medicine, 1995; 14 655-662

(3) ATS/ERS Task Force "Standardisation of Lung Function Testing", Standardisation of Spirometry, European Respiratory Journal 2005: 26: 319-338.

(4) European Respiratory Journal. Vol 6, Supplement 16 March 1993 Pages 26,27.

(5) Am J Respir Crit Care Med. 1999; 159:179-187

(6) J. Formosan Med. Assoc. 80; 19-29, 1981, Study on Maximal Expiratory Flow and Volume in Chinese, Min-Chien WU


Previous page